{"title":"1999-2002 Powerstroke 7.3L EGR Upgrades","description":null,"products":[{"product_id":"universal-airmouse-sensor-module-66420","title":"Universal AirMouse Sensor Module (66420)","description":"\u003ch6 style=\"text-align: left;\"\u003eDescription\u003c\/h6\u003e\n\u003cp style=\"text-align: left;\"\u003eThe AirMouse transforms your iDash into a mobile weather station that travels with your vehicle. This compact sensor provides real-time ambient air data and unique calculated metrics, helping you accurately assess your engine’s airflow. Install it in the grille, intake, or any spot where airflow measurement is needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number: \u003c\/strong\u003e\u003cspan\u003e66420 \u003c\/span\u003e\u003c\/p\u003e\n\u003ch6\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003eMonitor Ambient Air Density\u003c\/li\u003e\n\u003cli\u003eMeasures Ambient Temperature, Pressure, and Humidity\u003c\/li\u003e\n\u003cli\u003eAdds performance potential capabilities to the iDash\u003c\/li\u003e\n\u003cli\u003eMilitary grade \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003eInstallation\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2084\/8209\/files\/97660_Banks_b_bus_v6_web_d8d3e52e-cf8a-47c3-863a-4d600036336a.pdf?v=1752246040\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(138, 5, 26);\"\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial;\"\u003eBanks Bus Modules\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2084\/8209\/files\/97688_v2_Module_Installation_Insert_web.pdf?v=1752246045\"\u003e\u003cspan style=\"text-decoration: underline; color: rgb(138, 5, 26);\"\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial;\"\u003eBanks Derringer Module Install Addendum\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003eNotes\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003e 61301-20 Starter Cable required except for customers with a Derringer or other B-Bus Module already installed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003eAdditional Info\u003c\/h6\u003e\n\u003ch3\u003eAirMouse Exclusive Parameters Include:\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Air Density Mass (lbs of air per 1000 cubic feet)\u003c\/strong\u003e\u003cbr\u003eThe mass of dry air per unit volume of air measured at the location of the sensor. Density is a direct measurement of the oxygen available in the air for combustion and is calculated from the air's temperature, pressure, and humidity. The parameter is divided by 1000 to make the scaling easier to work with. (ex: 76.4 lb\/1kft^3 = 0.0765 lb\/ft^3).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Air Density % of Standard Day\u003c\/strong\u003e\u003cbr\u003eAmbient Air Density divided by a standard (either J607 or J1349) to normalize Density Mass to 100% for easier analysis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSAE J607 Correction Factor\u003c\/strong\u003e\u003cbr\u003eDyno correction factor to correct HP at varying altitudes and ambient temperature and humidity to a standard (J607 Standard: AAP = 14.7 psia, AAT = 60 F, RH = 0%, AAD = 76.35 lb\/1kft^3).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSAE J1349 Correction Factor\u003c\/strong\u003e\u003cbr\u003eDyno correction factor to correct HP at varying altitudes, ambient temperature and humidity to a standard (J1349 Standard: AAP = 14.35 psia, AAT = 77 F, RH = 0%, AAD = 72.17 lb\/1kft^3).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Air Pressure (psia)\u003c\/strong\u003e\u003cbr\u003eThe pressure of the air at the sensor reported in pounds per square inch absolute.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Air Pressure (kPa)\u003c\/strong\u003e\u003cbr\u003eThe pressure of the air at the sensor reported in Kilo Pascal absolute.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Air Pressure (in Hg)\u003c\/strong\u003e\u003cbr\u003eThe pressure of the air at the sensor reported in inches of Mercury.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Air Temperature (°F)\u003c\/strong\u003e\u003cbr\u003eThe temperature of the air at the sensor reported in deg Fahrenheit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Air Temperature (°R)\u003c\/strong\u003e\u003cbr\u003eThe temperature of the air at the sensor reported in deg Rankine.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Air Temperature (°C)\u003c\/strong\u003e\u003cbr\u003eThe temperature of the air at the sensor reported in deg Celsius.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Air Temperature (°K)\u003c\/strong\u003e\u003cbr\u003eThe temperature of the air at the sensor reported in deg Kelvin.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity (%)\u003c\/strong\u003e\u003cbr\u003eThe amount of water vapor present in air expressed as a percentage of the amount needed for saturation at the same temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrains H2O (grain\/lb air)\u003c\/strong\u003e\u003cbr\u003eA measurement of absolute humidity. The mass of water vapor in the air per lb of dry air. 7000 grains of H20 is equal to 1 lb of water.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDensity Altitude (ft)\u003c\/strong\u003e\u003cbr\u003eThe density altitude is the altitude relative to standard atmospheric conditions at which the air density would be equal to the indicated air density at the place of observation. In other words, the density altitude is the air density given as a height above mean sea level.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Altitude (ft)\u003c\/strong\u003e\u003cbr\u003ePressure altitude is defined as the altitude above or below the standard 29.92\" Hg standard datum plane. On a standard day, the pressure at sea level would be 14.7 psia (29.92\" hg). For every 1000' of altitude, there is an increase or decrease of about 0.5 psia (1\" hg).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Banks Power","offers":[{"title":"Default Title","offer_id":40309585313828,"sku":"66420","price":281.3,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2084\/8209\/files\/Universal-AirMouse-Sensor-Module-66420-Temp-Sensor-Harness-Plugs-Banks-Power-Canada.webp?v=1752276065"},{"product_id":"universal-xcelerator-tuner-cord-obd-ii-port-to-9-pin-511010000","title":"Universal Xcelerator Tuner Cord OBD-II Port To 9-Pin (511010000)","description":"\u003ch6\u003eDescription\u003c\/h6\u003e\n\u003cp\u003e\u003cstrong\u003eFits: \u003c\/strong\u003eUniversal\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eXcelerator Tuner Cord OBD-II port to 9-pin.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eXcelerator kits from PPE are perfect for those with stock motors \u0026amp; who just want something a little extra. \u003c\/span\u003e\u003cspan\u003ePPE Programmers are designed for peak performance and fuel efficiency, these tuners put the power in your hands. Easy-to-use interfaces and intuitive controls make it a breeze to fine-tune your vehicle for maximum power and efficiency. Rule the road like never before with PPE Power Programmers!\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 511010000\u003c\/span\u003e\u003c\/p\u003e\n\u003ch6\u003eFeatures\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003eXcelerator Tuner Cord \u003c\/li\u003e\n\u003cli\u003eOBD-II port to 9-pin\u003c\/li\u003e\n\u003cli\u003eSold Individually\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PPE","offers":[{"title":"Default Title","offer_id":41826700754980,"sku":"511010000","price":12.95,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2084\/8209\/files\/Universal-Xcelerator-Tuner-Cord-OBD-II-Port-To-9-Pin-511010000-Tuner-Harness-Plugs-PPE-Canada.webp?v=1738506635"}],"url":"https:\/\/www.dirtydieselcustom.ca\/collections\/1999-2002-powerstroke-7-3l-egr-upgrades.oembed","provider":"Dirty Diesel Customs","version":"1.0","type":"link"}